Rockwell Automation FactoryTalk Analytics PavilionX
Summary
<p><a href="https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-167-01.json"><strong>View CSAF</strong></a></p> <h2>Summary</h2> <p><strong>Successful exploitation of this vulnerability could result in an attacker executing privileged operations.</strong></p> <p>The following versions of Rockwell Automation FactoryTalk Analytics PavilionX are affected:</p> <ul> <li>FactoryTalk Analytics PavilionX <7.01 (CVE-2025-14272)</li> </ul> <div class="csaf-table"> <table class="tablesaw tablesaw-stack"> <thead> <tr> <th>CVSS</th> <th>Vendor</th> <th>Equipment</th> <th>Vulnerabilities</th> </tr> </thead> <tbody> <tr> <td>v3 7</td> <td>Rockwell Automation</td> <td>Rockwell Automation FactoryTalk Analytics PavilionX</td> <td>Missing Authorization</td> </tr> </tbody> </table> </div> <h3>Background</h3> <ul> <li><strong>Critical Infrastructure Sectors: </strong>Critical Manufacturing</li> <li><strong>Countries/Areas Deployed: </strong>Worldwide</li> <li><strong>Company Headquarters Location: </strong>United States</li> </ul> <hr /> <h2>Vulnerabilities</h2> <div class="csaf-accordion"> <p><a class="csaf-accordion-toggle-all" href="https://www.cisa.gov/">Expand All +</a></p> <div class="csaf-accordion-item"> <h3><a class="csaf-accordion-toggle" href="https://www.cisa.gov/">CVE-2025-14272</a></h3> <div class="csaf-accordion-content"> <p>A security issue was identified in Pavilion due to improper authorization enforcement in API endpoints. This vulnerability can allow an unauthorized actor to execute privileged operations, including user/role management and other administrative actions.</p> <p><a href="https://www.cve.org/CVERecord?id=CVE-2025-14272">View CVE Details</a></p> <hr /> <h4>Affected Products</h4> <h5>Rockwell Automation FactoryTalk Analytics PavilionX</h5> <div class="ics-vendor-version-status"> <div class="ics-vendor"><strong>Vendor:</strong><br />Rockwell Automation</div> <div class="ics-version"><strong>Product Version:</strong><br />Rockwell Automation FactoryTalk Analytics PavilionX: <7.01</div> <div class="ics-status"><strong>Product Status:</strong><br />known_affected</div> </div> <div class="ics-remediations"> <h6>Remediations</h6> <p><strong>Vendor fix</strong><br />Rockwell Automation recommends users update FactoryTalk Analytics PavilionX software to version 7.01 or later. The upgrade can be downloaded from the Rockwell Automation Download Center: https://www.rockwellautomation.com/en-us/support/product/product-downloads.html<br /><a href="https://www.rockwellautomation.com/en-us/support/product/product-downloads.html">https://www.rockwellautomation.com/en-us/support/product/product-downloads.html</a></p> <p><strong>Mitigation</strong><br />See Rockwell Automation's SD1777 advisory for more information: https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1777.html<br /><a href="https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1777.html">https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1777.html</a></p> </div> <p><strong>Relevant CWE:</strong> <a href="https://cwe.mitre.org/data/definitions/862.html">CWE-862 Missing Authorization</a></p> <hr /> <h4>Metrics</h4> <div class="csaf-table csaf-metrics-table"> <table class="tablesaw tablesaw-stack"> <thead> <tr> <th>CVSS Version</th> <th>Base Score</th> <th>Base Severity</th> <th>Vector String</th> </tr> </thead> <tbody> <tr> <td>3.1</td> <td>7</td> <td>HIGH</td> <td><a href="https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L">CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L</a></td> </tr> <tr> <td>4.0</td> <td>8.3</td> <td>HIGH</td> <td><a href="https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N">CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N</a></td> </tr> </tbody> </table> </div> </div> </div> </div> <hr /> <h2>Acknowledgments</h2> <ul> <li>Rockwell Automation reported these vulnerabilities to CISA</li> </ul> <hr /> <h2>Legal Notice and Terms of Use</h2> <p>This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).</p> <hr /> <h2>Recommended Practices</h2> <p>CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.</p> <p>Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.</p> <p>Locate control system networks and remote devices behind firewalls and isolating them from business networks.</p> <p>When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.</p> <p>CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.</p> <p>CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.</p> <p>CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.</p> <p>Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.</p> <p>Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.</p> <p>No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.</p> <hr /> <h2>Revision History</h2> <ul> <li><strong>Initial Release Date: </strong>2026-06-16</li> </ul> <table class="tablesaw tablesaw-stack"> <thead> <tr> <th>Date</th> <th>Revision</th> <th>Summary</th> </tr> </thead> <tbody> <tr> <td>2026-06-16</td> <td>1</td> <td>Initial Republication of Rockwell Automation advisory SD1777</td> </tr> </tbody> </table> <hr /> <h2>Legal Notice and Terms of Use</h2>